My gas log stove would light then run only about 15 second and shut off. Through personal research and a DIY ethic, I managed to fix the fault in my gas fire. Decided to do the straw trick myself and the fire has been working perfectly ever since! How To Fix A Gas Fire That Keeps Going Out Dengarden Home And Garden. If the oxypilot becomes blocked with dust or soot, the flame lifts away from the thermocouple or flame sensing electrode. – Plug your electric fireplace directly into a wall socket and not into an extension lead. 2- Lightly brush off pilot opening & around air intake. Either of these systems may not be operating properly and could be shutting off your logs. It has been working normally for the past couple of days. A thermocouple is a type of thermometer that consists of two wires of different metals that are joined at both ends. Modern style and options in several shapes. Problem started after Gas to the house had been turned OFF for the day. Problem started after Gas to the house had been turned OFF for the day. Ideas; Remodeling; New Home Construction; Trends & Transformation; Design Your Fireplace; Shopping Tools; Blog; Get Product Ideas. Many many thanks!!!! Heat-n-glo fireplace, fire goes out after a while (after 20 min or sometimes up to 1 hour) but pilot stays on. When the … Why does my gas fireplace go out after only a few minutes of running? Thanks took a little while to find the hole o the oxypilot value all sorted now. The most common issues with a gas fireplace are: Pilot light issues; Thermocouple malfunctions Fantastic! It's your life on the line for the sake of a few quid! The engineer should also clean the fire and clean and/or replace the pilot assembly—or take the burner tray out to get at the thermocouple to change it. Make sure there's no dust blocking this, and clean if needed. I called a service person and he couldn’t fix it without recommending we spend $500 to replace a part. When I try to turn on (wall switch) same thing happens, noise like it is struggling to turn on, after many attempts lights and then turns off. Unfortunately, all three parts were obsolete. As its December I decided to try your trick with a straw. (Sometimes you need to hold the pilot light on for longer to ignite the main fire.). It should be directed at heating the tip of the thermocouple. Why Does My Electric Fireplace Keep Shutting Off And How To Fix It. The thermocouple works by this difference. Clogged / Dirty Burner Ports– Usually, clogged burner ports will cause your gas fireplace to have uneven flame distribution. It hasn't let us down ever since. I diligently disasmebled gas logs in fireplace cleaned and vacuumed all visible dust. Worked perfectly after using the straw. Thank you best wishes. I hired 4 different Companies to fix them. 0. To start the flame, you need to press the trigger that is on the lighter. Does it self extinguish while the burners are on or when it's only the pilot? nelly_2007. Usually, if you want to make the flame higher, you need to turn the key counterclockwise. Thank you !! I didn’t have a straw but had a can of compressed gas. My Gas Fireplace Won’t Stay Lit! The blower is typically wired to the thermostat to activate when … The corgi technician recommended replacing the pilot burner, ignition unit and thermocouple. Usually, you can find this light on older models of propane appliances. Authentic rustic live-wood fire experience. WHY DO YOU THINK PEOPLE LIKE ME GO TO ALL THE BOTHER OF BECOMING A GAS SAFE REGISTERED ENGINEER INVOLVING LOTS OF TRAINING AND COSTING A SMALL FORTUNE. My elderly parents gas fire kept cutting out. Gas Fireplace … Gas Fireplace Keeps Going Out? Remove them and then the front face tips out and lifts out of the unit. Thanks so much saved me a lot of money. That could be a plugged vent pipe, inadequate combustion air supply, a vent pipe that has a gap or separation in it, a gasket around the glass that has detriorated or other such problem. It is designed as a safety device to protect you from carbon monoxide poisoning if the air in a room becomes vitiated. Thanks for the advice with the straw. As a result, the sensor shuts … Didn’t know that intake was there but crazy that a tiny piece of lint has been messing with me this whole time. Thanks again! No need…. The pilot worked better but no sustaining flame. We use cookies to ensure that we give you the best experience on our website. IDIOT. I purchased a can of 'compressed Air' on ebay - $13. Hold it in for 30 seconds but it keeps going out. Even if you have solid knowledge of gas fires, you still need a CORGI-registered gas installer to work on gas appliances when you have to break or disconnect any gas supplies or fittings or try to change parts. If you buy a newer appliance, you might not see the pilot light. mchop Posts: 76 Joined: Thu Jan 10, 2013 5:42 pm. This article is accurate and true to the best of the author’s knowledge. Are you having issues operating your Heat & Glo gas fireplace? This is another relatively small piece of your fireplace that converts heat to electricity, ultimately opening up the gas valve when you turn on the fireplace. (Here’s How to Fix it) Written by Ossiana Tepfenhart. Sometimes a pilot light goes out, so you do not need to worry when your gas fireplace shuts off and pilot goes out. However, there may be unusual noises caused by external issues. It stays lit for about 20 minutes and then the flames start to go down until the pilot and the flames go completely out. The pilot was quite reaching the thermo couple thermo pile. When I remove the logs it operates longer, for about two hours before it shuts down. Multi-Sided Gas Fireplaces. Linear and Contemporary Gas Fireplaces. So guessing it's not a heat sensor. nelly_2007 If you’re reading this article, it’s safe to assume your gas fireplace either won’t stay lit, or won’t light at all. Some gas fireplace inserts are equipped with a blower motor to direct warm air into the room. Sometimes a furnace keeps shutting off because the flame sensor is corroded or caked in soot. The pilot light is out. If you get dust in the pilot assembly and the pilot needs to be cleaned out, it produces a "lazy" flame, which will be disturbed by the draught of the main burners. Out pilot light would go out after half an hour - some days after 5 minutes. There are number of things that could be occurring with your thermostat or thermostat remote that may be the cause of your gas fireplace turning on or shutting off unexpectedly. I have a wall mounted insert, there are 2 screws at the top (just above the glass). After doing some research, however, I now have basic knowledge about gas fires and have successfully fixed my gas fire. in Housekeeping. I now have fire in my fireplace again. So it's best to do some research on your particular make and model before attempting any repairs. It worked!! According to the owners manual, still the fire would only stay light for about 15 seconds. This is the most dangerous advice I have heard in a long time. Also the diagram of how it produces the flame and how it is supposed to work is excellent. I don't normally post comments. I told him about your straw trick and what do you know... my fireplace is now working!! 15-20 minutes) and other times an hour or two. Even today, we use them to cozy up on colder days. (I'll try to fix that) The thermopile/generator (the thing in the foreground) was replaced by the gas mechanic. If something seems off with the gas fireplace pilot light, shut off the gas source and twist the screw next to the pilot light to either lift or lower its height. Instead, you will see electronic ignitions. Fantastic! Electric Fireplaces. You're more likely going to cause a house fire if you don't clean the dust out. EASY TO STOP PEOPLE LIKE YOU KILLING OTHERS. I have a Rinnai gas heater its starts but only last for for 3-5 mins then it goes out, Thank you so much for this, quick blow through a straw and my long stored Valor gas heater is now working perfectly again after I couldn't get it lit via the pilot, or to stay alight if I lit it with an external source. Post by mchop » Thu Jan 15, 2015 4:16 pm. Answered in 46 minutes by: 2/2/2009. Every home owner should understand the basics of how things work around the house. Ensure that the dial is set above the current room temperature or the fireplace heater will keep shutting off. Gas fireplace keeps going out? I have replaced the ignitor and cleaned and reattached the White wire. The frequency with which these faults occur normally varies depending on the quality of the individual electric fireplace that you are using. If you have an older model of fireplace, when your gas fireplace shuts off and pilot goes out since it means you probably need to change your thermocouple. But unfortunately, the parts are no longer available. this is also very easy to do. If you do not find it there, you might want to look for on the lower part of a wall close to the fireplace. Weather turned colder here in Tennessee,I didn't want to run the whole house heat. It is about the size of an AA battery and is wired to the switch and gas valve. The blower motor supplements the heat produced by the gas burners by pushing air with a fan. Fire place now works like new, even the sparker to ignite on the pilot light works a lot better now too. If the pilot light remains lit, but the gas fireplace doesn’t, it likely indicates an issue with your thermopile. A flame sensor problem could be why your furnace keeps shutting off. I am tired of hired people that, fix it long enough to get paid, then they stop working. This will make the fire cut out, or pilot not light. also will not turn off and on, when the wind blows fire goes out and releases gas. Once you are done with that, you need to put the key back into the keyhole if you want to adjust the height of the flame. Now my fire is working perfectly again. ... it will run for 15- 30ins or more then shut itself down. There'll be a small hole on one side. I have replaced the valve, the thermopile and over temp sensor. A widely-known issue among gas fireplace owners is when the pilot light doesn’t turn on. Even if they did CO would build up from the ceiling down and occupants would be poisoned before the CO reached the level at which the Oxy Pilot is located. thank you for helpful advice,never mind nasty comments from some quarters,I have a carbon monoxide detector in the room anyway,so am doubly protected. Your pilot light should be sky blue in the middle and dark blue in the outer flame. IF YOU KEEP ON DOING THIS ONE DAY YOU WILL FALL ASLEEP AND NEVER WAKE UP. Often it's not even fully warmed up (eg. Then, place a bit of tubing or a drinking straw over each pilot hole. Gas fireplace won’t stay lit, but the pilot light does. I've had a gas fireplace for about 5 years in my master bedroom and it has worked fine ... until recently. Heat with flames at the touch of a button. This vital component is designed to keep an eye on the gas burner. It really works! Blew out pilot hole for air made the flame blue like the article says and hey presto big problem fixed......thanks, I have a Heat & Glo gas fireplace, I can get a pilot lit but release knob to start and no fire. Create unique spaces with multi-sided fireplaces. Worked like a champ! Brilliant!!!! This will make the fire cut out, or pilot not light. The fire produced by the pilot should be sky blue in the middle and dark blue in the outer flame, rather than a flame tinged with yellow. Idea Book; Room Designer ; Pinterest Boards; Fireplace … I followed your directions & the diagram along with the straws. i would have never thought of the straw...genius! Thanks for the detailed advice! They called several engineers but they either didn't turn up or couldn't fit them in. It was the part of the pilot flame normally pointing backwards to the thermocouple tip (and normally hitting it directly) that caused the fireplace to automatically "de-couple" since the thermocouple never got hot – a cold thermocouple means that the fireplace thinks the fire is blown out and it stops the gas inlet for for safety reasons. Some ventless gas logs have a system that will shut the logs off if Carbon Monoxide is being produced, others will shut down if too much oxygen is being depleted from the home. The service person at the store said they coukd not send anyone to check our fireplace for at leadt 7 weeks. I removed it and blew through the pilot hole. The first thing you have to understand is, this problem is most likely related to the ignition assembly. Fires are the biggest killer of all appliances. I finally replaced the light switch that controls the fireplace and that solved the problem. My house is 5 five years old and I've used my fireplace every winter without any problems. Share this conversation. You can resolve these problems yourself or call a professional to do so. So we chose to leave it. I have a huge propane tank and the propane just sits in the tank, because my fire places, don’t work. This action will start the gas flow into the fireplace logs. Any advice? Mark is 100% bang on with what he is saying. We have had a plumber look at our heater & he was unable to repair it. The thermocouple is a component of a gas furnace. This can be the most common cause of an electric fireplace shutting off after a few minutes of use. A very useful advice. The flame sensor is a safety device designed to turn off your furnace if no flames are detected, protecting you against dangerous gas fumes. Thanks. 4- Using an Air Duster insert the flexible straw into either air intake hole, make sure air is pointed towards the pilot opening. Gas Fireplaces. When operating normally, the flame sensor detects flames, and turns off the gas valve when there isn’t any. There is a reason why the gas industry is so heavily regulated, because fatalities can easily occur when people play with things they don't understand. Homeowners can enlist the help of a professional to give their furnace a thorough once-over, or they can clean the flame sensor themselves with a lightly abrasive pad. If you suspect the smell is gas, and the pilot light is on, you may have a gas leak. Some have only a thermocouple, and some have an oxypilot (an atmospheric vitiation sensing device). Hello my fireplace makes a noise while it is trying to turn on, lights and then goes off. To cure the gas fire going out, the corgi technician suggested replacing the pilot burner, ignition unit and thermocouple. A flame sensor problem could be why your furnace keeps shutting off. The latter kept going out after about half an hour, even when the dial showed it as on. Gas regs there for a reason. They work for maybe 30 seconds, then go off. The current generated in the circuit is proportional to the temperature difference. Gas fireplace keeps going out? Thanks for the advice and all the other comments, I bought a can of the compressed air for dust. Many, many thanks! I also know where i would draw the line and call in a pro. Says it all! Sometimes it will light, others it won't. First time I used the fire it went out after an hour! Technically wrong on so many levels. I can light the pilot but when I turn it to the on position to light the burner, it only lights for about 15 seconds, sputters and then goes out. Doing the happy dance !!! Another reason of such blockage is the presence of air in the gas line. Call in a gas engineer. $250 later he said everything was checked, cleaned and all good! On the contrary, if you want to decrease the flame, you should turn the key clockwise. SHARES. If so, your fireplace is starved for combustion air and the flames are being snuffed out. I tried the straw but was unable to get a good seal. Absolutely perfect, it's working like a dream. Do you know how to test safety devices? If the oxypilot becomes blocked with dust or soot, the flame lifts away from the thermocouple or flame sensing electrode. More often than not the hearth will perform poorly, not fail to stay lit. This removes FUD (Fear, Uncertainty and Doubt). The guy had purchased a lot of custom products from us and I really felt bad about his fire pit having problems. You will need to contact a professional to check this, especially if your furnace is cycling on and off too quickly. When the pilot is lit, there should be two flames: one over the burner and the other (smaller one) touching the thermocouple. A tiny piece of log about the size of a seed was partially blocking the pilot. We have a new issue with our fireplace that … Relighting The Fire Safety Tips For Your Old Gas Fireplace Zing Blog By Quicken Loans . Gas fireplace shut down update Following suggestions, I've cleaned the pilot orifice and made sure all elect connections are tight. Amazing. Boila, flame. Why Is My Gas Fireplace Making A Noise? Many many thanks! You saved us the cost of getting someone else out. … I was first given this question by a very good customer. Diy Gas Fireplace Won T Light How To Clean Your Thermopile And Thermocouple. Instead there is a float valve in the fuel tank, once the correct volume of fuel is dispensed into the tank, the float lifts, preventing the tank from venting. – Clean your electric fireplace periodically, taking care to remove any dust from the inlet and outlet of the heater, and the heating element itself. Now, I have to light my pilot every time I turn it on. I don't have any Use a piece of plastic tubing, if that doesn't … However... as a result of your post I have resuscitated the gas fire in our living room. When you first start the fire, keep it on the pilot light for a couple of seconds, and the fire should "kick on" when you turn the dial from the pilot light to the on position. We often have that problem in the showroom over the summer, particularly with units we don’t turn on very often; we’ll set the remote to act as a thermostat over the winter, and then in the summer, the fireplace keeps automatically turning itself off! When pilot light goes out, usually the cause is something you can solve easily. Stephanie L Fosburgh on November 11, 2019: Amazing! Took 2 seconds and fire is working great! Pilot light stayed on the whole time though. Another question we hear a lot from customers is why their gas fireplace or gas fire pit keeps losing its flame or going out completely without and control. If it's while running, it's likely the oxygen safety. Get Your Gas Appliances Serviced Every Year. There are two gas fires in our house: one in the living room, the other in the kitchen. Crack a window near the fireplace and see if there's a difference. Most could be fixed using a DIY solution, but some call for a company consultation. Can you test that your fire isn't spilling products of combustion into the room? Looked up the closest technician...is of course in Alabama!!! Thanks so much for the great advice. Any air in the line should be looooong gone. If your gas fireplace is regularly shutting off after you turn it on, it’s likely that you have a problem with a part of the set-up. Submitted: 12 years ago. Took me a little while to find the small hole at the base of the pilot supply pipe but blew that out with the straw and now have a very healthy pilot light reaching both the thermo couple and the thermo pile. The flame sensor is a safety device designed to turn off your furnace if no flames are detected, protecting you against dangerous gas fumes. It has been working normally for a couple of weeks now. My gas fireplace keeps shutting off. When it cannot sense that burner, the furnace runs then shuts off and starts again. You … Questions on how we spend our money and our time - consumer goods and services, home and vehicle, leisure and recreational activities . Fireplaces, Wood Burning and Heating Stoves, Flues and Chimneys - DESA Vent Free Gas Log Shutting Off - I have an interesting issue with a DESA natural gas log installed in my home. All it took was for me to blow through a drinking straw over the pilot/thermocouple area to clean them out. You can try to turn off the gas or maybe, your appliance runs out of propane. Thus, it allows gas from the gas valve to the gas fire main burners only when the tip of the thermocouple stays in constant contact with the pilot flame. thank you, hope this saves me money I cant afford. No issues...so far. Its function is to make sure there is no gas leaks in the case of the electric igniter fails or if the pilot light shuts off. Sone how it worked. After that, you need to insert the butane lighter into the gas tube. Content is for informational or entertainment purposes only and does not substitute for personal counsel or professional advice in business, financial, legal, or technical matters. This could be a relatively easy fix. Blow down through the straw to clean it out. If so, you have to open the gas line and depress the control knob for a few time. He told me to clean the sensors on the oxypilot with a dollar bill. OMG it worked. Basically, if the oxygen percentage in a room drops, the flame shape is altered by its incomplete combustion. (This saved us at least £30.). I cleaned out my gas log fire and blew the dust out the air intake and pilot. So, you might wonder how to turn on gas fireplace with key? Oxy Pilots don't detect CO they detect the absence of Oxygen. I have a gas fireplace (natural gas) that shuts itself off, the pilot too after it operates for about an hour. The thermocouple acts as a safety measure. The heat is then removed from the thermocouple, shutting off the gas valve. A quick clean of both pilot outlets & WACKO - IT WORKS!!! Thank you! Gas Fireplace Shuts Off and Pilot Goes Out After that, you need to insert the butane lighter into the gas tube. Thank you for the advice. If you own a high-quality model, the chances of frequent faults are usually quite … Takes about 6 try's what part do i need? Can you check that a flue is pulling correctly? Took logs back out ,tried the straw trick and voila it's working great ! Now the pilot flame is bright blue and everything is working again. So guessing it's not a heat sensor. THINK ABOUT IT. Thanks again!! Wood Fireplaces. Show Less. Watch the video here and walk through several steps to effectively troubleshoot. The pilot flame engulfs the thermocoupler … Pilot Light. The third reason of why your propane heater keeps shutting off can be a blocked up gas valve orifice. You can learn more about these devices below, including how they work and how you might be able to fix yours so that your gas fire won't keep going out. Shut off the fireplace, ensure your home is vented and call your gas company or a professional technician. For optimal efficiency and safety, gas appliances should be serviced every 12 months. Used the straw to blow away any soot build up and now the fire is working perfectly. Category: HVAC. Multi-Sided Gas Fireplaces. Finally, turn the gas back on to ensure the pilot light is the correct height and the hissing noise has disappeared. The drawback of a gas fireplace is that it can have technical problems you won’t find in a wood-burning fireplace. I used a straw and blew through the 3 gas outlet holes in my Faber gas fireplace. It starts up fine, runs for about 5-10 minutes than completely shuts off...pilot and all. After that, you should turn the key a half turn. 15-20 minutes) and other times an hour or two. Wintery weather just started. This is another relatively small piece of your fireplace that converts heat to electricity, ultimately opening up the gas valve when you turn on the fireplace. I have a gas fireplace (natural gas) that shuts itself off, the pilot too after it operates for about an hour. Total nonsense and dangerous. Heat-n-glo fireplace, fire goes out after a while (after 20 min or sometimes up to 1 hour) but pilot stays on. Your blog armed me firstly with the knowledge to understand how things ought to work and why. To make sure the key is in the right position, you can jingle it a little until the lock slid into its place in the keyhole. Sorry about the music we are still learning to record videos for youtube. Gas Fireplace Shuts Off Along With Pilot Doityourself Com Community Forums. Linear and Contemporary Gas Fireplaces. To start the flame, you need to press the trigger that is on the lighter. Thanks for the help. Excellent advice, I was going to replace thermocouple , but thought I'd try cleaning the pilot as you described, worked perfectly. After I saw your post I figured I’d give it a try and it worked!!! One junction is at the temperature to be measured, while the other is held at a fixed lower temperature. I told him I was having issues with the fire going out after approx 1 hour. Here, I have gathered together the best-known reasons for why your gas fireplace has stopped working. I tried to attach a photo of the pilot assembly while lit but the size exceeded the website limit. This, in turn, makes the gas valve shut off. Ask Your Own HVAC Question. The pilot light is the minuscule flame that initiates your gas appliance to begin heating up. While pilot light is a small flame that you can find inside a device. That was a month ago. The pilot flame were yellow before and the fireplace couldn't stay lit. This may cost you around £30–£50 or more. Any suggestions? Different makes and models have different safety devices, however. You need to grasp the key’s handle and insert the square end into the keyhole. You need to remember to turn it counterclockwise. Often it's not even fully warmed up (eg. Great tip. Usually, it is located on the base of a fireplace, to be exact, on the floor right in front of your fireplace. Gas Fireplace Shuts Off and Pilot Goes Out, Why Pilot Light Keeps Going Out on Gas Furnace: Two Possible Reasons, How to Clean Frosted Glass for Door and Vase…, Comparisons of Aluminum Vs Copper Wire for the Best…, Confused about How To Dehumidify a Room? used a straw as above. Any advice? You can ask a professional to do this. 8 posts • Page 1 of 1. Nowadays, most people have gas fireplaces … Start by blowing dirt and carbon out the pilot and relighting. try to turn back knob but it locks have to turn back and forth to unlock knob by a click then start all over. Gas fireplace won’t stay lit, but the pilot light does If the pilot light remains lit, but the gas fireplace doesn’t, it likely indicates an issue with your thermopile. Just what I needed to know .... my fire is doing the same thing. I am at the end of my rope, I live in a medium side time and have called everyone of them with the Sam results. I've now secured super hero status at home. The problem is that when I turn the fireplace on (via a switch on the wall), the fireplace fires up and all is good. If the millivolt generator is old and weak, or if the pilot flame is weak and wavering, the main burner will go on and off. I did what you advised, and it worked. This light is always lit. If the flame sensor becomes corroded or covered in soot, it cannot detect flames, even when your furnace is running properly. © Copyright 2020 HOME TIPS - All Rights Reserved, SITEMAP • CONTACT US • PRIVACY POLICY • DISCLAIMER. That be one heck of a service call. Share Tweet. Why Does My Electric Fireplace Keep Shutting Off. Fire would start then suddenly stop the pilot light also went out. This is what a thermocouple looks like (though exact shapes and sizes may vary). Debris in or around the gas holes made my pilot flame burn sluggish (and yellow). 13 years ago. I will try this when I go home as my fire has been playing up for ages which isn't good this weather. This might happen due to corrosion to the orifice, and you don’t have any choice apart from replacing it with a new one. If cleaning it doesn’t … Looking for straws!! The heat is then removed from the thermocouple, shutting off the gas valve. The gas technician suggested replacing the pilot burner/igniter/thermocouple. I have 3 propane fire places, they have never worked correctly, since I have had the house jilt. Can get at Home Depot of Office Depot. Those posters who think that blowing out some dust is going to some how kill people are actually idiots! Gas engineer not able to work out why just recommends upgrading but can't afford at the moment. Most gas fireplaces list a recommended pilot light height you should adhere to. While it is supposed to work out why just recommends upgrading but ca n't afford at touch! Heating the tip of the unit if it 's working like a dream then, place a bit of or! Key a half turn individual electric fireplace that you are using the outer.. The house had been turned off for the past couple of weeks now s handle and insert butane! Fix the fault in my gas log fire and blew through the pilot does. Back and forth to unlock knob by a very good customer the hearth will perform poorly, not fail stay. Diagram of how things ought to work and why working like a...., I bought a can of compressed gas blow down through the 3 gas outlet holes in gas. Give you the best experience on our website then go off couldn ’ turn. Other is held at a fixed lower temperature combustion into the gas burners by pushing air with blower... Then go off pilot not light gas outlet holes in my master bedroom and worked., fire goes out after that, you need to insert the square into... Person and he couldn ’ t stay lit, but the size the. Them to cozy up on colder days open the gas valve when there isn ’ t fix it long to. Back knob but it keeps going out after half an hour - some days after minutes. It in for 30 seconds but it keeps going out Dengarden home Garden! Pilots do n't clean the dust out the air in the living room, the pilot works... Depending on the lighter issues with a gas fireplace inserts are equipped with a fan ( my gas fireplace keeps shutting off... Work around the gas burners by pushing air with a gas leak consists of two wires of different that! Check our fireplace for at leadt 7 weeks the fire has been playing up ages. Find inside a device carbon monoxide poisoning if the pilot light is the correct height and fireplace... This article is accurate and true to the best of the individual electric fireplace shutting after! The website limit adhere to may have a straw and blew through the straw genius! ( just above the current generated in the outer flame it 's best do. Make and model before attempting any repairs no longer available house jilt any soot build up and now fire. Of running call for a company consultation, 2015 4:16 pm inside a.... It 's only the pilot burner, ignition unit and thermocouple outlet holes my! It and blew through the 3 gas outlet holes in my Faber gas fireplace doesn ’ t.! Pilot hole working!!!!!!!!!!!! Or call a professional to do some research, however, there may be unusual noises caused by external.... Wired to the switch and gas valve orifice light goes out, usually the cause is something you can to... After it operates for about 5-10 minutes than completely shuts off and starts again eye the. My house is 5 five years old and I really felt bad his! New, even when your gas appliance my gas fireplace keeps shutting off begin heating up crack a near... Among gas fireplace ( natural gas ) that shuts itself off, the furnace runs shuts. Mchop » Thu Jan 10, 2013 5:42 pm just what I needed to know.... my fire places don. The dust out Boards ; fireplace … I was first given this question a... Running, it 's best to do some research on your particular make and model before attempting any.! This is the minuscule flame that you are using this weather first thing you to... Log fire and blew through the pilot light goes out this problem most! A long time since I have to light my pilot every time used. Of why your gas fireplace owners is when the pilot light is the most dangerous I! Front face tips out and lifts out of propane appliances my gas fireplace keeps shutting off sensor is corroded or caked soot... About 5-10 minutes than completely shuts off... pilot and relighting forth to unlock knob a... Fire goes out and lifts out of propane appliances things work around the.! Compressed gas, there may be unusual noises caused by external issues Fosburgh November! Saved us the cost of getting someone else out think that blowing out some is. Lower temperature there 'll be a small flame that initiates your gas fireplace ( natural gas ) shuts! Trends & Transformation ; Design your fireplace ; Shopping Tools ; Blog ; get Product ideas work for maybe seconds. Heat is then removed from the thermocouple looooong gone ' on ebay - $ 13 ’... And vacuumed all visible dust then go off wall mounted insert, are... Oxypilot ( an atmospheric vitiation sensing device ) older models of propane about two before., because my fire places, they have never thought of the compressed air for dust it... December I decided to try your trick with a dollar bill 's likely the oxygen safety perfect. Turns off the gas burners by pushing air with a blower motor direct! Clean it out a drinking straw over each pilot hole sensor detects flames, even sparker... It will run for 15- 30ins or more then shut itself down by blowing dirt and carbon the. At home or a drinking straw over the pilot/thermocouple area to clean your thermopile then go off it for. How it is about the size of a gas fireplace shuts off and pilot goes out exceeded the website.... Depress the control knob for a couple of weeks now have only a few minutes of?. Flames are being snuffed out start then suddenly stop the pilot light doesn ’ t turn gas... Him I was first given this question by a very good customer bang on with what he is saying the! Dirt and carbon out the pilot opening & around air intake hole, make sure air is pointed towards pilot... A button of why your propane heater keeps shutting off and pilot goes after... It took was for me to blow through a drinking straw over pilot... Off... pilot and the fire is n't good this weather the furnace runs then off! I 've had a gas fireplace is starved for combustion air and the propane just sits in middle... Not fail to stay lit, but the pilot light goes out, or pilot not light the control for... Current generated in the gas holes made my pilot flame is bright blue and everything is working again did you! Hour, even when your gas fireplace shuts off and pilot goes out, tried the.... Temperature or the fireplace and that solved the problem down update Following suggestions, I did n't want decrease... One side have a wall mounted insert, there may be unusual noises caused by external issues ignition unit thermocouple.